JETCO TS-1000 Torque
Meter Sending data from the TS-1000 to a computer
The TS-1000 has a standard RS232c communication port. Use this port to send data to a computer to log torque data and to create torque files for traceability.
You can also use this port to send directly to a serial dot matrix printer.
The data is sent in ASCII format with the following protocol: Bits per second: 4800 Data bits: 8 Parity: None Flow Control: None
You can send the data out the TS-1000 communication port in two ways:
1. Press the save key and the individual data on the display will be sent (you must be in peak or first peak mode). 2. Enter the menu mode, scroll to “send mem” press save and send ALL the data in memory.
The data is sent as follows: DDD TTTT UUUU 0000
Where: DDDD is the data number TTTT is the torque value UUUU is the torque units 0000 Not used Example:
043 -317.7 lbf.ft. 0000 (the zero’s are not used)
This is data number 43, the value is –317.7 and the units are lbf.ft..
HOW TO SET UP THE COMPUTER AND THE METER: 1. Determine which com port is available on your computer (usually comm. 1) 2. Plug the computer to meter adapter in the com port that is available 3. Plug the telephone type cord into the computer adapter and the meter com port 4. Under the Windows desktop select the following: Start-Programs-Accessories-Communications-Hyperterminal Select the Hypertrm icon Name the new connection “torque” or “TS-1000”. Press OK Select the com port that you are using under “Connect using” box. Press OK Port Settings: Bits per second: 4800 Data Bits: 8 PARITY: NONE Stop Bits: 1 Flow Control: None Press OK You will now be connected. Press the Send key to verify that data is coming in. If the data is not recognizable, do the following:
Select File-Properties Select Settings from the properties window Emulation: ANSI Select ASCII Setup. Check the Append line feeds to incoming line ends. Press OK. Press OK Disconnect the connection by selecting Call-Disconnect Reconnect the connection by selecting Call-Call Press the Save key to verify the data is being sent.
See the Windows operation manual on how to create files within the Hyperterminal window.
Sending to a printer: Refer to the printer operation manual for instructions on how to set the printer to ASCII-4800BPS-8-1-n.
JETCO 1808 E. Evergreen St. Duarte, CA 91010 www.itorque.com |
|
JETCO 626-359-2881 Fax: 626-359-8315 www.itorque.com |